Part |
Stabilized Rejection |
Size (inches) |
Flow Rate |
|
Number |
|
Diameter x Length |
GPD |
| 1. |
TW30-1812-16 |
98.0 |
1.75 x 11.75 |
16 |
| 2. |
TW30-1812-24 |
98.0 |
1.75 x 11.75 |
24 |
| 3. |
TW30-1812-36 |
98.0 |
1.75 x 11.75 |
36 |
| 4. |
TW30-1812-50 |
98.0 |
1.75 x 11.75 |
50 |
| 5. |
TW30-1812-75 |
98.0 |
1.75 x 11.75 |
75 |
| 6. |
TW30-1812-100 |
90.0 |
1.75 x 11.75 |
100 |
| 7. |
Culligan 36 |
(clone) |
1.75 x 11.75 |
36 |
| 8. |
Rainsoft-22 9568 |
(clone) |
1.75 x 10.00 |
22 |
| 9. |
Rainsoft-50 956 |
(clone) |
1.75 x 10.00 |
50 |
|
Part |
Size (inches) |
Test |
Flow Rate |
Stabilized
|
|
Number |
Diameter x Length |
Psi |
GPD |
Rejection |
| 10. |
TW30-2013 |
1.8 x 13 |
225 |
100 |
99.00 |
| 11. |
TW30-2026 |
1.8 x 26 |
225 |
220 |
99.0 |
| 12. |
TW30-2514 |
2.5 x 14 |
225 |
200 |
99.0 |
| 13. |
TW30-2521 |
2.5 x 21 |
225 |
325 |
99.0 |
| 14. |
XLE-2521 |
2.5 x 21 |
100 |
365 |
99.0 |
| 15. |
TW30HP-2540 |
2.5 x 40 |
225 |
600 |
99.0 |
| 16. |
TW30-2540 |
2.5 x 40 |
225 |
850 |
99.5 |
| 17. |
TW30HP-2540 |
2.5 x 40 |
225 |
1000 |
99.0 |
| 18. |
LP-2540 |
2.5 x 40 |
145 |
850 |
99.2 |
| 19. |
XLE-2540 |
2.5 x 40 |
100 |
850 |
99.0 |
| 20. |
TW30-4014 |
4.0 x 14 |
225 |
525 |
99.0 |
| 21. |
TW30-4021 |
4.0 x 21 |
225 |
900 |
99.0 |
| 22. |
XLE-4021 |
4.0 x 21 |
100 |
1025 |
99.0 |
| 23. |
TW30-4040 |
4.0 x 40 |
225 |
2400 |
99.5 |
| 25. |
TW30HP-4040 |
4.0 x 40 |
145 |
2700 |
99.2 |
| 26. |
XLE-4040 |
4.0 x 40 |
100 |
2600 |
99.0 |
| 27. |
TW30HP-4611 |
4.6 x 11 |
225 |
1200 |
99.0 |
| 28. |
TW30HP-4619 |
4.6 x 19 |
225 |
1450 |
99.0 |
| 29. |
TW30HP-4641 |
4.6 x 41 |
225 |
5200 |
99.0 |
| 30. |
TW30-4014 |
4.0 x 14 |
225 |
850 |
99.0 |
| 31. |
BW30-4040 |
4.0 x 40 |
225 |
2400 |
99.5 |
| 32. |
BW30-4040-FR |
4.0 x 40 |
150 |
2200 |
99.5 |
| 33. |
BW30LE-4040 |
4.0 x 40 |
225 |
2300 |
99.2 |
| 34. |
BW30-365 |
8.0 x 40 |
225 |
9500 |
99.5 |
| 35. |
BW30-365 FR |
8.0 x 40 |
225 |
9500 |
99.5 |
| 36. |
BW30-400 |
8.0 x 40 |
225 |
10500 |
99.5 |
| 37. |
BW30-400 FR |
8.0 x 40 |
225 |
10500 |
99.5 |
| 38. |
BW30LE-440 |
8.0 x 40 |
150 |
11500 |
99.2 |
| 39. |
XLE-440 |
8.0 x 40 |
100 |
12700 |
99.0 |
| 40. |
HSRO-4040-FF |
4.0 x 40 |
150 |
1900 |
99.5 |
| 41. |
RO-3838-30-FF |
4.0 x 40 |
225 |
2000 |
99.0 |
| 42. |
RO-3838-30-FF |
4.0 x 40 |
225 |
2650 |
99.5 |
| 43. |
HSRO-390-FF |
8.0 x 40 |
150 |
9000 |
99.5 |
| 44. |
RO-390-FF |
8.0 x 40 |
225 |
11500 |
99.5 |
| 50. |
SG30-400 |
8.0 x 40 |
150 |
10200 |
99.5 |
| 51. |
SG30LE-430 |
8.0 x 40 |
150 |
10000 |
99.5 |
| 60. |
NF90-2540 |
2.5 x 40 |
225 |
520 |
85-95 |
| 61. |
NF-2540 |
2.5 x 40 |
225 |
920 |
99.0 |
| 62. |
NF270-2540 |
2.5 x 40 |
225 |
850 |
40-60 |
| 63. |
NF90-4040 |
4.0 x 40 |
225 |
1500 |
85-95 |
| 64. |
NF200-4040 |
4.0 x 40 |
225 |
1850 |
35-50 |
| 65. |
NF-2540 |
4.0 x 40 |
225 |
2700 |
99.0 |
| 66. |
NF270-4040 |
4.0 x 40 |
225 |
2500 |
40-60 |
| 67. |
NF90-400 |
8.0 x 40 |
225 |
7500 |
85-95 |
| 68. |
NF200-400 |
8.0 x 40 |
225 |
8000 |
35-50 |
| 69. |
NF-400 |
8.0 x 40 |
225 |
11000 |
99.0 |
| 70. |
NF270-2514 |
8.0 x 40 |
225 |
12500 |
40-60 |
| 80. |
SW30-2514 |
2.5 x 14 |
800 |
150 |
99.4 |
| 81. |
SW30-2521 |
2.5 x 21 |
800 |
300 |
99.4 |
| 82 |
SW30-4040 |
2.5 x 40 |
800 |
700 |
99.4 |
| 83. |
SW30-4021 |
4.0 x 21 |
800 |
800 |
99.4 |
| 84. |
SW30-4040 |
4.0 x 40 |
800 |
1950 |
99.4 |
| 85. |
SW30HR-4040 |
4.0 x 40 |
800 |
1200 |
99.7 |
| 86. |
SW30-6040 |
6.0 x 40 |
800 |
2100 |
99.4 |
| 89. |
SW30HR-320(ov) |
8.0 x 40 |
800 |
5000 |
99.7 |
| 90. |
SW30HR-320(nv) |
8.0 x 40 |
800 |
6000 |
99.7 |
| 91. |
SW30-380 |
8.0 x 40 |
800 |
9000 |
99.4 |
| 92. |
SW30HR-380 |
8.0 x 40 |
800 |
6000 |
99.7 |
| 93. |
SW30HR LE-380 |
8.0 x 40 |
800 |
7500 |
99.7 |
HP = High Production (up to 225 psi)
HR = High Rejection
LE = Low Energy (operate 50 to 150 psi)
FR1 = Fouling Resistant for potable water
FF = Full Fit (food or pharmaceutical)
FR2 = Fouling Resistant for nonpotable water
a) The GPD rates are based on a pressure of 100psi.
b) The NF
270-2540 replaces the NF55-2540 and the NF70-2540.
c) The NF 270-4040
replaces the NF55-4040 and the NF70-4040.
d) The NF-4040 replaces the
NF45-4040.
e) The NF90-400 or NF270-400 replaces the NF 70-400.
* The TW30-PF2012-125 can be operated on water with 500 or less TDS
with pressure as low as 30 psi.
COMMERCIAL PRESSURE VESSELS
| PVC |
| Part # |
Pressure |
| PVC-2026 |
220 psi |
| PVC-2514 |
220 psi |
| PVC-2521 |
220 psi |
| PVC-2540 |
220 psi |
| UltraT-4014 |
150 psi |
| UltraT-4021 |
150 psi |
| UltraT-4040 |
150 psi |
| FIBERGLASS |
| Part # |
Pressure |
| Pentair-4040 |
250 psi |
|
(Codeline) |
| PVF-4014 |
400 psi |
| PVF-4021 |
400 psi |
| PVF-4040 |
400 psi |
| STAINLESS
STEEL |
| Part # |
Pressure |
| PVS-2514 |
300 psi |
| PVS 2521 |
300 psi |
| PVS-2540 |
300 psi |
| PVS-4014 |
300 psi |
| PVS-4021 |
300 psi |
| PVS-4040 |
300 psi |
| PVS-4080 |
300 psi |
| Other stainless steel is also
available. |
PUMPS & MOTORS
Procon Pumps
| Series |
Formerly Called |
GPH |
Description |
| 2 |
1500 Series |
15-140 |
Brass, 3/8" NPT Ports |
| 3 |
1600 Series |
15-140 |
St. Steel, 3/8" NPT Ports |
| 4 |
2500 Series |
115-330 |
Brass, 1/2" NPT Ports |
| 5 |
2600 Series |
115-330 |
St. Steel 1/2" NPT Ports |
| 6 |
3600 Series |
300-660 |
1" NPT Ports |
CMP- 7500 |
Motor/Pump Combo |
15-140 |
3/8" NPT Ports |
When ordering, please specify whether you want "bolt on" or "clamp
on" style.
Series 6 available in "bolt" style only